OPTIMA® BlueTop TrollFury (case only) [TROLLFURY]  £20.70 
 

Kit Model: TrollFury
Part Number: 988112
Nominal Voltage: 12 volts or 24 volts
NSN: N/A
Description: Kit that requires additional purchase of two BT DC 4,2, high power, dual purpose engine start and deep cycle, sealed lead acid batteries

Physical Characteristics:
Plate Design: High purity lead-tin alloy. Wound cell configuration utilizing proprietary SPIRALCELL® technology.
Electrolyte: Sulfuric acid, H2SO4
Case: Polypropylene
Color: Case: Light Gray
Cover:  OPTIMA Blue

 StandardMetric
Length:
Width:
Height:
Weight:
23.25
8.5
8.5
90 lb..
581 mm
213 mm
213 mm (height at the top of the terminals)
40.8 kg


Terminal Configuration: Threaded stainless steel stud 5/16 .

Performance Data:

 12 Volt24 Volt
Capacity:
Reserve Capacity:
110 Ah (C/20)
BCI: 240 minutes
(25 amp discharge, 80°F
(26.7°C), to 10.5 volts cut-off)
55 Ah (C/20)
BCI: 120 minutes
(25 amp discharge, 80°F
(26.7°C), to 10.5 volts cut-off)



Power:

 12 Volt24 Volt
CCA (EN -18°C):
MCA (BCI 0°C):
1530 amps
1740 amps
765 amps
870 amps



Recommended Charging:
The following charging methods are recommended to ensure a long battery life:
(Always use a voltage regulated charger with voltage limits set as described below.)
Model: BT SLI 4,2
These batteries are designed for engine starting applications. They are not recommended or warranted for use in deep cycle applications.

OPTIMA® BlueTop TrollFury

Recommended Charging Information Based on 12 V Set-up:
Alternator: 13.65 to 15.0 volts
Battery Charger: (Constant Voltage) 13.8 to 15.0 volts; 10 amps maximum; 6-12 hours approximate
Float Charge: 13.2 to 13.8 volts; 1 amp maximum current (indefinite time at lower voltages)
Rapid Recharge: (Constant voltage charger) Maximum voltage 15.6 volts. No current limit as long as battery temperature remains below 50°C (125°F). Charge until current drops below 1 amp.
All limits must be strictly adhered to.

Recharge Time-24 V:
(example assuming 100% discharge  10.5 volts)

CurrentApprox. time to 90% charge
100 amps
50 amps
25 amps
35 minutes
75 minutes
140 minutes

Recharge Time-12 V: (example assuming 100% discharge  10.5 volts)

CurrentApprox. time to 90% charge
100 amps
50 amps
25 amps
70 minutes
150 minutes
280 minutes


Recharge time will vary according to temperature and charger characteristics. When using Constant Voltage chargers, amperage will taper down as the battery becomes recharged. When amperage drops below 1 amp, the battery will be close to a full state charge.

(All charge recommendations assume an average room temperature of 25°C, 77°F)

Always wear safety glasses when working with batteries.

Always use a voltage regulated battery charger with limits set to the above ratings. Overcharging can cause the safety valves to open and battery gases to escape, causing premature end of life. These gases are flammable! You cannot replace water in sealed batteries that have been overcharged. Any battery that becomes very hot while charging should be disconnected immediately.

Not fully charging a battery can result in poor performance and a reduction in capacity.

Shipping and Transportation Information:

OPTIMA batteries can be shipped by AIR. The battery is nonspillable and is tested according to ICAO Technical Instructions DOC. 9284-AN/905 to meet the requirements of Packing Instructions No. 806 and is classified as non-regulated by IATA Special Provision A-48 and A-67 for UN2800. Terminals must be protected from short circuit.

Available Options:
This product was added to our catalog on Tuesday 06 March, 2007.
  Reviews  
  Add to Wishlist  
Quantity:     
Shopping Cart more
0 items
Log In 
Password Forgotten?
Currencies